2 Year Warranty on All products

Allen-Bradley 1756-L61

Allen-Bradley 1756-L61

Allen-Bradley 1756-L61

Regular price
$3,290.00
Sale price
$3,290.00
Checkmark

In stock - Ships Today

Checkmark

Eligible for Next Day Delivery

Checkmark

Ships From Our North Carolina Warehouse

Eligible for Next Day Delivery All Parts Come with 24 Month Warranty New, Refurbished and Repairs Available


We can ship via UPS, FedEx, and USPS. We can ship on customers' accounts as well. International delivery available via UPS and DHL. In stock items typically ship same day.


All products (new, refurbished, and repairs) are covered by the Industrial Automation Company's 2 Year Warranty. Manufacturer's Warranty does not apply.


Payment options

We accept all major credit cards. Arrangements can be made for Wire Transfers and PayPal payments.

Credit Terms

We understand that credit is a necessary part of business. We offer NET 30 terms to established companies.

Description

Industrial Automation Co. is NOT an Authorized Rockwell Distributor - we have our own unique inventory and sourcing relationships. Review our Reseller notice‚ here.

  • 1756L61
  • DISCONTINUED BY MANUFACTURER 06/01/2017
  • REPLACEMENT CONTROLLOGIX 1756-L71
  • CPU MODULE
  • 2 MB MEMORY
  • CONTROLLOGIX 5561
  • 2 MB
  • 1.2 AMP
  • 24 VDC

All products (new, refurbished, and repairs) are covered by the Industrial Automation Company's 2 Year Warranty. Manufacturer's Warranty does not apply.

Buying Options
Buying Options

All products are covered by Industrial Automation Co.'s 2-Year Warranty.

Condition SKU Price Warranty Availability Quantity Purchase
Surplus Original Open Box 1756-L61-NSO 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
Surplus Original Box 1756-L61-FS $3,290.00 USD 2 Year Extended Warranty 1 In Stock in US!
Quick Repairs and Great Service

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Quick Search

TECHNICAL SPECIFICATIONS

The Allen-Bradley 1756-L61 ControlLogix controller module is suited for usage in most medium-scale applications with the required I/O capacity. Additional modules, such as communication modules, specialist and intelligent modules, and encompass partner modules, may be fitted to improve the module’s functioning.

It has 478 Kb of available Input/Output memory and 2 MB of user memory. A 1784-CF128 CompactFlash memory card may be used to provide 128 MB of additional non-volatile storage capacity as an option. It is a chassis-based controller that may be installed in any open slot on the ControlLogix chassis 1756. This controller is compatible with the following chassis: 1756-A17, 1756-A4, 1756-A10, 1756-A13, and 1756-A7.

It features an open-style enclosure and can support as many as 250 controller connections. Additionally, it includes an integrated RS-232 serial communication port. The DF1 full/half-duplex protocols, DH-485, DF1 radio modem, and ASCII, are all supported by the RS-232 serial port.

The 1756-L61 controller module has 32 controller tasks, each with 100 programs. It supports several communication channels, including ControlNet, Data Highway Plus (DH+), EtherNet/IP, DeviceNet, SynchLink, and external device and process networks.

The 1756-L61 controller module consumes 14 mA @ 24V dc and 1200 mA @ 5V dc. Power dissipation is 3.5 Watts, while thermal dissipation is 11.9 BTU per hour. It also features a constant isolation voltage of 30V that has been tested for 60 seconds at 720V dc.

Its operational temperature range is 0 to 60 °C, and its maximum exterior air temperature tolerance is 60 °C. Its storage temperature range is -40 to 85 °C. While the non-operating shock is 50 G, the operational shock is 30 G. The vibration frequency is 2G between 10 and 500 Hz, and the relative humidity ranges from 5% to 95% (noncondensing).

The implementation of standalone and distributed I/O applications is supported by this controller. The network connections may differ depending on the communication module utilized. Additionally, it provides redundancy, which is generally needed in important systems to increase system availability.

Along with analog input possibilities, including encoder input, LDT input, and SSI input, this controller also features an integrated motion system through the embedded SERCOS (serial real-time communication system) interface. This module may implement motion across an Ethernet/IP network if used in conjunction with an Ethernet communication module.

Relay Ladder Logic (RLL), Structured Text (ST), Function Block Diagram (FBD), and Sequential Function Chart (SFC) are among the programming languages that the controller supports.

An RS-232 communication cable is necessary to communicate with the module. The user software and data are stored in the memory of this module using a battery. The battery versions 1756-BA1, 1756-BATM, and 1756-BATA are suitable for series A controllers, while the 1756-BA2 battery is suitable for series B controllers.

ManufacturerIndustrial Automation
BrandAllen-Bradley
Part Number/Catalog No.1756-L61
SeriesControlLogix
Module TypeProcessor Module
Fixed Memory2, 4, or 8 MB
Nonvolatile MemoryCompact Flash Card 1784-CF128
Maximum I-O128,000
CommunicationRS-232 serial port
RS232 ProtocolsASCII DF1 full/half-duplex DF1 radio modem DH-485 Modbus via logic
Maximum Analog I-O4,000
Program Scan Time0.08 milliseconds
User Memory2MB
Backplane Current (5Volts DC)1.2 Amps
Backplane Current (24 Volts DC)14 milliamps
Weight0.71 pounds (0.32 kilograms)
Vibration10-500 Hertz
UPC10612598300706
Relative Humidity5-95 percent
Battery1756-BA1, 1756-BATM or 1756-BATA
UNSPSC32151705
Product Lifecycle Status*Discontinued/Obsolete
Programming SoftwareRedundancy
Full SupportProgramming Languages

*The Allen Bradley 1756-L61 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1756-L61 units instead of migration.