Honeywell On-Off Primary Burner Control With VPS

Honeywell On-Off Primary Burner Control With VPS - RM7890B1048/U

SKU: RM7890B1048/U

Estimated delivery: April 20th - April 22nd

Order for next-day shipment.

This product is not available for online purchase.

Use the Request a quote to get the pricing

Default Title
Available
Request a quote

Description

The Honeywell On-Off Primary Burner Control with VPS is designed to operate at a frequency of 50/60 Hz, providing an intermittent main flame establishing period and an optional 4 or 10-second pilot flame establishing period. Additionally, it includes a shutter drive capability, a VPS check feature, and offers an LED fault indication system for error annunciation.

The unit is highly functional, incorporating an array of operation modes including automatic burner sequencing, flame supervision, system status indication, as well as both system and self-diagnostics for efficient troubleshooting. Notably, the product houses an inbuilt valve-proving feature which, for setup purposes, necessitates the S7800A1142 keyboard display, sold separately. Operation of the burner control requires both a subbase and amplifier.

For error indication, the power LED presents fault codes in a series of blink sequences, while enhanced features include a Modbus interface, keyboard display module, and a remote display module. For system sequencing, there are five informative LEDs, and the inclusion of interchangeable plug-in amplifiers offers adaptability. Operational and fault annunciations can be displayed either locally or remotely via the optional S7800 keyboard display module.

To secure essential data, the controller comes equipped with non-volatile memory, retaining history files and lockout status even following a loss of power. Users can choose between relight or lockout on the event of flame loss. The Honeywell On-Off Primary Burner Control with VPS functions optimally under an operating temperature range of -40 F to 140 F.

More payment options

Secure payment options

  • Guaranteed response within 24 hours

    Submit an RFQ and receive a quick, reliable quote from our team to keep your operations moving.

    More about shipping
  • 24 month warranty

    Twice the industry standard—full protection against defects for 2 full years.

    More about warranty
  • Multiple conditions available

    Multiple sourcing paths to help you control costs without compromising performance.

    More about warranty
  • Best catalog

    Large U.S. inventory and fast sourcing for Mitsubishi, Siemens, Schneider & more.

    Read More
  • Buying Options

    All products are covered by Industrial Automation Co.'s 2-Year Warranty.

    Condition SKU Price Warranty Availability Quantity Purchase
    Default Title RM7890B1048/U 2 Year Extended Warranty Call for Availability Call for Availability (877)-727-8757
  • Description

    The Honeywell On-Off Primary Burner Control with VPS is designed to operate at a frequency of 50/60 Hz, providing an intermittent main flame establishing period and an optional 4 or 10-second pilot flame establishing period. Additionally, it includes a shutter drive capability, a VPS check feature, and offers an LED fault indication system for error annunciation.

    The unit is highly functional, incorporating an array of operation modes including automatic burner sequencing, flame supervision, system status indication, as well as both system and self-diagnostics for efficient troubleshooting. Notably, the product houses an inbuilt valve-proving feature which, for setup purposes, necessitates the S7800A1142 keyboard display, sold separately. Operation of the burner control requires both a subbase and amplifier.

    For error indication, the power LED presents fault codes in a series of blink sequences, while enhanced features include a Modbus interface, keyboard display module, and a remote display module. For system sequencing, there are five informative LEDs, and the inclusion of interchangeable plug-in amplifiers offers adaptability. Operational and fault annunciations can be displayed either locally or remotely via the optional S7800 keyboard display module.

    To secure essential data, the controller comes equipped with non-volatile memory, retaining history files and lockout status even following a loss of power. Users can choose between relight or lockout on the event of flame loss. The Honeywell On-Off Primary Burner Control with VPS functions optimally under an operating temperature range of -40 F to 140 F.

  • Documentation

    AI Product Assistant

    Ask questions about Honeywell On-Off Primary Burner Control With VPS - RM7890B1048/U

    AI Assistant

    Ask questions about Honeywell On-Off Primary Burner Control With VPS - RM7890B1048/U

    Suggested questions

Quick search

Send in your item for a free evaluation and repair quote. Use our RMA form or email a repair request to service@iac.us.com , and we will contact you to assess your situation and offer shipping information.

Technical Support

Need help with installation, configuration, or troubleshooting? Our technical experts are available to assist you.

  • Phone Support

    (877) 727-8757

  • Email Support

    sales@iac.us.com

Order Your Industrial Automation Parts Today

Industrial Automation Co. is a premier supplier of replacement and aftermarket industrial components. In addition to the On-Off, we offer hundreds of Honeywell parts available now in our warehouse. Most of our automation components ship on the same day and are covered by our two-year service warranty. Contact us to order your Honeywell replacement parts today.